100 Series Reciprocating Compessor Unit

  • 100 Series Reciprocating Compessor Unit Manufacturers, 100 Series Reciprocating Compessor Unit Factory, Supply 100 Series Reciprocating Compessor Unit
  • 100 Series Reciprocating Compessor Unit Manufacturers, 100 Series Reciprocating Compessor Unit Factory, Supply 100 Series Reciprocating Compessor Unit
  • 100 Series Reciprocating Compessor Unit Manufacturers, 100 Series Reciprocating Compessor Unit Factory, Supply 100 Series Reciprocating Compessor Unit
  • 100 Series Reciprocating Compessor Unit Manufacturers, 100 Series Reciprocating Compessor Unit Factory, Supply 100 Series Reciprocating Compessor Unit
  • 100 Series Reciprocating Compessor Unit Manufacturers, 100 Series Reciprocating Compessor Unit Factory, Supply 100 Series Reciprocating Compessor Unit
100 Series Reciprocating Compessor Unit
  • Bingshan
  • China
  • 60-90days
  • 3000 set/year

Scope
26.7~512kW(-15℃/30℃)
Refrigeration capacity: 26.7~512kW (standard condition -15℃/30℃)
Application
Widely used in various fields need to achieve artificial refrigeration, such as petroleum, chemical industry, pharmaceutical, cryogenic laboratory of national defense and scientific research, food low temp processing, storage and transportation, and low temperature test, low temperature processing of food storage and transportation, air conditioning in factories, hospitals and other large public places building.

100 Series Reciprocating Compessor Unit

Features

Adopt Y series of high efficiency energy-saving motors, protection class IP23

Unit is with high speed, small size and interchangeable parts

Compressor shaft seal and gasket are import brand.

provided energy adjustment device to realize unit start without load

Equipped with three-way oil drainage valve. Oil can be charged during normal operation

Safe and reliable operation

 


SERIES 100 RECIPROCATING COMPRESSOR UNIT TECHNOLOGY PARAMETER TABLE


Model

Unit

2AZ10

4AV10

6AW10

8AS10

4ASJ10

8ASJ10

Unit

Refrigeration Capacity

Standard Condition

KW

26.7

54

81.4

108

17.5 Condition

--35℃/+35℃

37.2 Condition

--35℃/+35℃

Air Conditioning Condition

54

116

174.4

232.6

Shaft Power

Standard Condition

KW

8.12

16

23.8

31.6

10.1 Condition

--35℃/+35℃

20.4 Condition

--35℃/+35℃

Air Conditioning Condition

12

24

36

48

Compressor

Theoretical Displacement

m3/h

63.3

126.6

190

253.3

31.65(94.95)

63.3(190)

Capacity Regulating Range



0,1/1,2

0,1/3,2/3,1

0,1/4,1/2,3/4,1

0,1/3,2/3,1

0,1/3,2/3,1

Suction Pipe Dia.

Mm

50

50

65

80

32(50)

40(65)

Discharge Pipe Dia.

Mm

40

50

65

80

32(50)

40(65)

Cooling Water Consumption

Kg/h

300

500

750

1000

500

1000

 

Note:·Conditions: Signle-stage: the maximum discharge pressure ≤ 1.5MPa, the maximum discharge temperature ≤150℃, the maximum pressure ≤1.4MPa; two-stage: Low stage, the maximum discharge pressure ≤0.7Mpa, Maximum discharge temperature ≤120℃, the maximum pressure ≤0.8MPa; High stage, the maximum discharge pressure ≤1.5MPa, the maximum discharge temperature ≤150℃, the maximum pressure ≤1.4MPa.

·  Data in parentheses are the low stage parameters

·  Standard condition: -15℃/30℃. Air conditioning: +5℃/+40℃



Ammonia Reciprocating Compessor Unit

Get the latest price? We'll respond as soon as possible(within 12 hours)
close left right