Indoor Type Single Semi-hermetic R22 Compressor Unit (3HP~20HP)4.61kw~38.41kw
Indoor Type Single Semi-hermetic R404a Compressor Unit (3HP~7HP)4.89kw~15.30kw
Application
Widely applied in small-type cold storage with out-sourcing air cooled condenser

Semi-hermetic Reiprocating Compressor Unit

Features

1. High Reliability

2. Excellent compressor techniques ensure the leading position and reliability of Sanyo Semi-hermetic Compressor Unit.

3. Optional Wiring Elements for Defrost

4. Wring elements for showcase or air cooler are optional. Defrosting timer is computerized controlled to enhance reliability and makes operation more convenient.

5. Fan Cooling

6. Compressor fan cooling avoids the loss of refrigerant energy caused by liquid injection cooling.

 

 

 

n Semi-hermetic Reiprocating Compressor Unit Technology Parameter Table

Type

Refrigerant

Norminal Condition

Low Temp condition

Evap. Temp. Range

Cond. Temp. Range

Compressor

Noise

Outline

Net Weight

Ref. Cap.

Input Power

Ref. Cap.

Input Power

Displacement/Unit

Cooling Method

L

W

H



kw

Kw

Kw

kw

m3/h


dB(A)

mm

mm

mm

kg

LCU-32PJ

R22

4.61

2.38

1.84

1.29

-5~-40

-7~43

9.14

Forced Air Cooler

56

780

590

608

84

LCU-42PJ

R22

6.94

3.65

2.476

1.76

-5~-41

-7~44

13.64

Forced Air Cooler

57

850

506.5

813

142

LCU-52PJ

R22

8.78

4.33

3.63

2.44

-5~-42

-7~45

18.18

Forced Air Cooler

58

850

506.5

813

142

LCU-62PJ

R22

12.72

6.12

4.96

3.36

-5~-43

-7~46

23.11

Forced Air Cooler

60

861

506.5

813

149

LCU-72PJ

R22

14.15

6.9

5.92

3.63

-5~-44

-7~47

25.41

Forced Air Cooler

61

861

506.5

813

152

LCU-100PJ

R22

23.25

8.99

6.41

5.52

-5~-45

-7~48

45.41

Forced Air Cooler

68

1171

600

910

240

LCU-150PJ

R22

27.06

10.59

8.73

6.74

-5~-46

-7~49

52.55

Forced Air Cooler

68

1171

600

910

250

LCU-200PJ

R22

38.41

16.45

11.95

10.33

-5~-47

-7~50

73.52

Forced Air Cooler

68

1400

625

985

260

LCU-N32PJ

R404A

4.89

2.39

2.1

1.25

-5~-48

-7~51

9.1

Forced Air Cooler

55.5

780

590

608

84

LCU-N42PJ

R404A

8.21

3.57

3.33

1.98

-5~-49

-7~52

13.6

Forced Air Cooler

57.5

506

850

813

142

LCU-N52PJ

R404A

10.92

4.76

4.44

2.64

-5~-50

-7~53

18.2

Forced Air Cooler

57.5

506

850

813

142

LCU-N62PJ

R404A

13.91

6.06

5.65

3.36

-5~-51

-7~54

23.1

Forced Air Cooler

58

506

861

813

149

LCU-N72PJ

R404A

15.3

6.67

6.21

3.69

-5~-52

-7~55

25.4

Forced Air Cooler

58

506

861

813

152

Note

 

Ref. Cap, input power and displacement test condition (nominal condition): Evap. Temp: -6.7℃, Cond. Temp: 48.9℃, Suction Temp.: 10℃,  Ambient Temp: 35℃

Ref. Cap, input power test conditions(low temp condition): Evap. Temp.: -30℃ Cond. Temp.: 45℃

In low temp condition, LCU-100PJ and LCU-150PJ units are installed SPK-RF410 cooling fan.

In low temp condition, LCU-200 is installed SPK-RF510 cooling fan.

Noise value is tested in front of unit within 1m x 1m at nominal condition. The actual noise value could be different as per actual condition.